A composting facility consists of various infrastructures designed to facilitate the composting process efficiently and in accordance with environmental regulations. Key infrastructures in a composting facility include:
Reception area (for incoming sludge and bulking material)
Pre-processing area (for pretreatment of sludge or bulking material)
Active composting area (for the actual composting process)
Storage areas for finished compost (before distribution or sale)
Pathways (for easy access)
Leachate and stormwater management systems (to prevent runoff and potential environmental impacts)
Buffer zones (to help control odours and as a barrier between the facility and neighbouring properties)
Washing facilities (for workers)
The active composting area is recommended to be capable of accommodating 30 days of compost production. The specific area requirements for the actual composting depends on the composting method used as each requires a different approach.
In this topic, we shall look into determining the area required specifically for the compost, relevant to the following composting methods:
Aerated static pile composting
Passive aerated box composting
Windrow composting
Aerated static pile composting
The formula to calculate the required composting area is as follows:
Where,
Parameter
Description
Unit
A
Pad area for the aerated static pile *
m2
VS28
Total sludge volume in 28 days **
m3
VB28
Total bulking agent volume 28 days
m3
H
Height of the compost pile ***
m
* The pile area should be increased by 10% for the aerated static pile system for the odour-control filter. ** The equation assumes a 21-day composting period and provides 7 additional days for low temperature, excess precipitation, and malfunctions. Achieved by active aeration. *** The typical height of the active aerated static pile is between 2 and 2.5m.
Exercise:
We want to compost 5 m3 of dewatered faecal sludge per day, with a mixing ratio of dewatered sludge to bulking agent as 1:1. The bulk density of wood chips is assumed to be 200 kg/m3. The height of the compost is assumed to be 2.5 m as an excavator would load. As a reminder, the volume of the respective feedstock materials is determined by multiplying the mass with density.
Parameter
Description
Unit
Value
A
Pad area for the aerated static pile
m2
–
VS28
Total sludge volume in 28 days
m3
140
VB28
Total bulking agent volume 28 days
m3
735
H
Height of the compost pile
m
2.5
Solution:
The required area for composting of the aerated static pile is 385 m2.
Passive aerated box composting
The formula to calculate the required composting area is as follows:
Where,
Parameter
Description
Unit
A
Compost area for box composting *
m2
VS/d
Total sludge volume per day
m3/d
VB/d
Total bulking agent volume per day
m3/d
VAB
Volume aeration box **
m3
CC
Composting cycle ***
d
AAB
Area of aeration box
m2
* The calculation does not include the areas necessary for air circulation between the box composts (0.75m) and the access paths.
** The box dimensions are typically 1.2-1.5m wide, 3-6m long, and 1.2-1.3m high.
*** Nr of days required for composting with passive aeration could range from 30 to 60 days
Exercise:
We want to explore the area requirement for passive aerated box composting as an alternative to active aeration due to the lack of power and availability of low-cost labour. Specifically, we want to determine the required composting space to compost 5 m3 of dewatered sludge, assuming a mixing ratio of 1:1 for dewatered sludge to bulking agent (as previously established for optimal C:N). The bulk density of wood chips is assumed to be 200 kg/m3. The composting box dimensions are 1.5 m in width, 6 m in length, and 1.3 m in height. The composting cycle will take 40 days with passive aeration.
Parameter
Description
Unit
Value
A
Compost area for box composting
m2
–
VS/d
Total sludge volume per day
m3/d
5
VB/d
Total bulking agent volume per day
m3/d
25.25
VAB
Volume aeration box
m3
11.7
CC
Composting cycle
d
40
AAB
Area of aeration box
m2
9
Solution:
The required area for composting is 961.5 m2.
Windrow composting
Firstly, we use the following formula to determine the length of each windrow:
Where,
Parameter
Description
Unit
l
Length of windrow
m
VS/d
Total sludge volume per day
m3/d
VB/d
Total bulking material volume per day
m3/d
w
Width of windrow
m
h
Height of windrow
m
Secondly, we are required to add 1.5 – 2 m for each side of the pile for the lateral circulation area and calculate each site and the area of each pile.
Where,
Parameter
Description
Unit
Aw
Area of windrow
m2
lA
Lateral lengths around windrow
m
wW
Width of windrow
m
lW
Length of windrow
m
Finally, we calculate the total area when a number of piles is equal to the number of days in the compost cycle.
Where,
Parameter
Description
Unit
A
Total area
m2
Aw
Area of windrow
m2
CC
Compost Cycle
d
Exercise:
We want to explore the area requirement for windrow composting as an alternative. Specifically, we want to determine the required composting space to compost 5 m3 of dewatered sludge, assuming a mixing ratio 1:1 for dewatered sludge to bulking agent (as previously established for optimal C:N). The bulk density of wood chips is assumed to be 200 kg/m3. The windrow is triangular, and because it is turned manually, the height is 1.5m, the width is 3 m, additional lateral area is assumed to be 2 m per side. The composting cycle is assumed to be 60 days.
This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Strictly Necessary Cookies
Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.
3rd Party Cookies
This website uses Google Tag Manager to collect anonymous information such as the number of visitors to the site, and the most popular pages.
Keeping this cookie enabled helps us to improve our website.
Please enable Strictly Necessary Cookies first so that we can save your preferences!