When planning for safe infiltration, it is important to ensure that the following conditions are met:
Setback distances
The location of infiltration systems must maintain a minimum distance from other existing structures, infrastructures, or natural elements. Local regulations may specify the requirements. The table below summarises recommendations for the minimum distances that must be maintained. Adhering to these distances ensures a sufficient buffer to prevent any potential contamination or health risks.
Reference Point
Horizontal Distance to Reference Point (m)
Well or spring used for water supply
30 – 35
Lake or stream, marsh, or pond
15
Consumption water line
3
Property boundary
3
Residence
5
Drain
5
Top of an embankment
3
Tree
2
Recommended Distances between Infiltration System and Selected Reference Points
Soil suitability
The soil where infiltration is planned should have suitable properties for effective percolation and filtration. These properties may include soil texture, structure, permeability, and depth to the water table (the bottom of the infiltration system is recommended to be at least 1.5 m above groundwater level). Soil testing and analysis are often conducted to assess soil suitability. A percolation test is considered a must prior to the implementation of an infiltration system.
Adequate pre-treatment
Pre-treatment (primary and secondary) of wastewater before infiltration is critical to remove solids and contaminants that could harm the infiltration system or the receiving soil. This may include using biodigesters, anaerobic baffled reactors, trickling filters, or other treatment units. The effluent should be tested to guarantee that it is suitable for discharge into an infiltration system. The recommended BOD and TSS levels for effluent infiltration into the soil depend on soil texture and hydraulic loading.
Scheduling and loading
The rate at which effluent or wastewater is introduced into the infiltration system must be carefully controlled to avoid overloading and potential environmental harm. The system should include a dosing system with proper scheduling to ensure adequate loads and time between loads. Also, it is essential to ensure that an even distribution of wastewater across the infiltration system is realised.
While local regulations should always be considered, the following table summarizes some typical characteristics of infiltration systems and applications that should be avoided.
Characteristic
Typical Application
Application to Avoid
Type of wastewater
Domestic and commercial
Facilities with non-sanitary and/or industrial wastewater
This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
Strictly Necessary Cookies
Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.
If you disable this cookie, we will not be able to save your preferences. This means that every time you visit this website you will need to enable or disable cookies again.
3rd Party Cookies
This website uses Google Tag Manager to collect anonymous information such as the number of visitors to the site, and the most popular pages.
Keeping this cookie enabled helps us to improve our website.
Please enable Strictly Necessary Cookies first so that we can save your preferences!